0 kva ups 10000va ups price online industrial ups
10000va ups key features:
a).Pure sine wave output, true on-line dual conversion design
b).Adopt 4 layers PCB, and SMD technology
c).High efficiency IGBT (insulated gate bipolar transistor) inverter technology
The 6th generation low-exhaust and big-power IGBT with excellent high speed switch feature, high voltage feature and large current feature. Drives by electric voltage, only need small control power. The 6th generation with lower saturation voltage, the inverter has high efficiency, low temperature, high reliability.
d).Touch screen display, with the simple operation and Intuitive data, optional display language and logo
e).Set the work mode on the display directly, UPS mode, ECO mode, EPS mode
f). Intelligent detecting function
This system microprocessor can continually online detect power status, the breaker status and all the working status of the circuit.
g).Excellent load feature
It is completely capable to load from 0-100% while no need to change to bypass, which makes sure the output reliable.
h).Cold start
When mains failure, can directly use the battery to start the ups until the battery discharge to low voltage, when mains recover, can self start UPS.
i).Generator compatible
According to the real electric circumstance, UPS can be compatible to the generator, highly improve the generator input efficiency, save the energy.
j).Intelligent communication
With RS232 and RS485 standard collocation, optional SNMP and dry contact
k).Perfect protection
Input/output over/low voltage protection, input surge protection, phase sequence protection, battery over charge/discharge protection, short circuit protection, over-temperature protection and so on, as well as alarm function.
l).Selectable battery inspection module
Can test the single parameter and display on the LCD, battery failure will immediately alarm and inform the administrator.
m).High-powered dynamic feature
Adopt kinds of feedback control such as instantaneous control mode and virtual value, not only reach the high dynamic adjustment, but also reduce the output voltage distortion.
n).Optional input harmonic filter
Effectively restrain the input THD, raise UPS input power factor and reduce the input THD current.
10000va ups technical specifications:
Model | L1K | L2K | L3K | L4K | L6K | L8K | L10K | L15K | L20K |
Nominal capacity(KVA) | 1KVA | 2KVA | 3KVA | 4KVA | 6KVA | 8KVA | 10KVA | 15KVA | 20KVA |
Working principle | Pure sine wave |
Phase | 1 phase +N+G |
Input power factor | >0.85 |
Rectifier | Input voltage | 220VAC; 230VAC; 240VAC |
Range | ±25% |
Nominal input frequency | 50Hz±10%; 60Hz±10%; |
Output ripple | <2% |
Soft startup | 0~100% 5s |
Charge | Charge mode | Constant current to constant voltage, with temp compensation; with auto change |
Float voltage | 55VDC | 220VDC |
Boost voltage | 56.8VDC | 227VDC |
Temperature compensation voltage | 3mV/°C(monomer) |
Charge current | 0.1C(automatically change according to battery capacity) |
Charge power | 40% of rated capacity |
Battery | Battery type | Maintenance-free lead acid battery |
Battery capacity | 7~999AH settable (according to the capacity) |
Battery number | 4pcs 12V | 16pcs 12V |
Inverter | Phase | 1 phase |
Rated power | Rated capacity×0.8 |
Nominal voltage | 220VAC; 230VAC; 240VAC |
Output voltage stability | ±1%(stable load); ±5%(fluctuant load) |
Output frequency stability | 50Hz/60Hz<±0.5% |
Crest factor | >3:1 |
Output waveform distortion | Pure sine wave, linear load<3%; non-linear load<5% |
Dynamic characteristics | Instant voltage<±5%(from 0 to100%), instant recover time<10ms |
Unbalanced load voltage | <±5% |
Overload protection | 125% 1 minute; 150% 1s |
Efficiency | >93%(full load) |
Bypass | Phase | Single phase + N |
Nominal voltage | 220VAC; 230VAC; 240VAC |
Transfer time | <1ms(static switch with 0s) |
Protection | Input protection | Input voltage/frequency over limited protection |
Output protection | Over current; short circuit; factor low protection |
Battery protection | Over charge; over-discharge protection |
Temperature protection | Environment over temperature protection; inverter over temperature protection |
Hardware failure protection | Assistant power abnormal, breaker cut off, breaker overload, power devices over current/over voltage etc. protection |
System Parameters | Working environment | Temp: 0~40ºC, relative humidity 30%~90% (1% decrease against 100 meters’ rise, altitude 4000 meters Max) |
Cooling down method | Compulsive ventilation(with temperature control) |
Communication interface | RS232/RS485; optional SNMP card(for internet) |
Redundancy function | Tandem hot backup or parallel connection |
Anti-surge capacity | 10/700μS, 5KV; 8/20μS, 20KA |
Protection level | IP21 |
Safety performance | Vin-n Vout-n 3000Vac, creepage<3.5mA, insulating resistance>2MΩ(500VDC) |
Noise(dB) | 45~60 |
Dimension(W×D×H)mm | 210*452*510 | 220*578*540 | 380*900*680 | 430*750*1050 |
Weight(Kg) | 35 | 58 | 65 | 82 | 105 | 200 | 245 | 265 | 300 |
| | | | | | | | | | | |