Hybrid inverter charger MPPT controller charger and AC grid charger all in one
inverter charger Key features:
1. LED/LCD optional
2. Selectable settings for flooded lead acid, gel, or absorbed glass mat (AGM) batteries
3. 70A automatic 3-stage battery charging (bulk, absorption, and float) for increased performance
4. Low battery, overload, and high battery, over temperature protection circuitry
5. Fast switching (grid to battery and battery to grid) for backup power
6. 3W or 10w low idle load power
7. Durable construction for long life under extreme environmental conditions
8. Simplified controls with a snap-on cover that protects settings from being accidentally changed
9. Better thermal performance allows full output power to 50°C (122°F) without de-rating
10. 3:1 surge capability starts more difficult loads and handles overload conditions reliably
11. Generator compatible
inverter charger Technical specifications:
General specifications: |
Input wave form: | Sine wave(Utility or generator) |
Nominal voltage: | 120VAC | 230VAC |
Low voltage trip: | 90V+/-4% | 184V/154V+/4%- |
Low voltage re engage: | 100V+/-4% | 196V/164+/-4% |
High voltage trip: | 140V+/-4% | 253V+/-4% |
High voltage re engage: | 135V+/-4% | 243V+/-4% |
Max input AC voltage: | 150VAC | 270VAC |
Nominal input frequency: | 50Hz or 60Hz(Auto detect) |
Low frequency trip: | 47Hz for 50Hz, 57Hz for 60Hz |
High frequency trip: | 55Hz for 50Hz, 65Hz for 60Hz |
Output wave form: | (Bypass mode) same as input |
Overload protection: | Circuit breaker |
Short circuit protection: | Circuit breaker |
Transfer switch rating: | 30 amp or 40 amp |
Efficiency on line transfer mode: | 95%+ |
Line transfer time: | 10 ms typical |
Bypass without battery connected: | Yes |
Max bypass current: | 30 amp or 40 amp |
Bypass over load current: | 35 amp or 45 amp: alarm |
Inverter specification/output |
Output wave form: | Pure sine wave or quasi sine wave |
Output continuous power watts: | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 |
Output continuous power VA: | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 |
Power factor: | 0.9-1.0 |
Nominal output voltage rms: | 120/230VAC |
Output voltage regulation: | +-/10% rms |
Output frequency: | 50Hz+/-0.3Hz or 60Hz+/-0.3Hz |
Nominal efficiency: | >88% |
Surge ratings: | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 |
Short circuit protection: | Yes, fault after 10 secs |
Inverter specification/input: |
Nominal input voltage: | 12V | 24V | 48V |
Minimum start voltage: | 10V | 20V | 40V |
Low battery alarm: | 10.5V | 21V | 42V |
Low battery trip: | 10V | 20V | 40V |
High voltage alarm: | 16V | 32V | 64V |
Power saver: | Below 25 watts when enabled |
Power saver: | Same switched on/off on remote |
Charger mode specifications: |
Input voltage range: | 95-127VAC | 194-243VAC/164-243VAC(W) |
Output voltage: | Dependent on battery type |
Charger current: | 35A/70A |
Battery initial voltage for start up: | 0-15.7V for 12V(*2 for 24V; *4 for 48V) |
Over charger protection shutdown: | 15.7V for 12V(*2 for 24V; *4 for 48V) |
Charger curves (4 stage constant current) battery types |
4 steps digital controlled progressive charge |
Battery type: | Fast V | Float V(*2 for 24V; *4 for 48V) |
GEL U.S.A. | 14.0 | 13.7 |
A.G.M. 1 | 14.1 | 13.4 |
A.G.M. 2 | 14.6 | 13.7 |
Sealed lead acid | 14.4 | 13.6 |
GEL Euro | 14.4 | 13.8 |
Open lead acid | 14.8 | 13.3 |
Calcium | 15.1 | 13.6 |
De-sulphation | 15.5 for 4 hrs |
Remote control/RS232/USB | Yes, optional |
Size: in mm | 1000/2000/3000 model: 442*218*179 mm3 |
| 4000/5000/6000 model: 598*218*179 mm3 |
Net weight: | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 |
| 18Kg | 20Kg | 22Kg | 35Kg | 38Kg | 40Kg |